Difference between revisions of "20ma current loop to RS-232 conversion"
(adding more resources. Schematic at circuitlab) |
(→Schematic 1.1: added sub section headings) |
||
(7 intermediate revisions by the same user not shown) | |||
Line 8: | Line 8: | ||
[[File:TTY RS-232 Back.png|400px]] | [[File:TTY RS-232 Back.png|400px]] | ||
− | == | + | ==Additional Resources== |
+ | * Helpful article, [http://www.vintagecomputer.net/teletype101.cfm Teletype 101] from vintagecomputer.net | ||
* Another circuit. From [[http://altairclone.com/teletype.htm Altairclone]] Specifically designed to fit in a Teletype model 33 using only a 12vdc wall wart for power. | * Another circuit. From [[http://altairclone.com/teletype.htm Altairclone]] Specifically designed to fit in a Teletype model 33 using only a 12vdc wall wart for power. | ||
− | * Another [https://www.circuitlab.com/circuit/mnartk/screenshot/1024x768/ circuit] I found referenced on the greenkeys email list | + | * Another [https://www.circuitlab.com/circuit/mnartk/screenshot/1024x768/ circuit] I found referenced on the greenkeys email list |
+ | |||
+ | ==My ASR hookup== | ||
+ | I built the circuit described above from the altairclone site. I found the Teletype 101 article helpful for identifying the proper terminal strip locations. The interface works. I set baud to 110, with 7 bits and 'mark' parity in TeraTerm on a windows 8 notebook with a Gigaware USB<> serial convereter. | ||
+ | |||
+ | ===Schematic 1.1=== | ||
+ | From the original schematic at altairclone I added ASR terminal strip location numbers. | ||
+ | |||
+ | [[File:RS-232 to ASR-33 Teletype Interface Schematic v1.1.jpg]] | ||
+ | ===Wiring legend=== | ||
+ | <source lang="text"> | ||
+ | screw wire schematic | ||
+ | Signal terminal color connection | ||
+ | (Teletype 101 nomenclature) (on ASR) (mine) (altair clone nomenclature) | ||
+ | --------------------------------------------------------------------- | ||
+ | Transmitted data send (+) 7 orange Data to Teletype + | ||
+ | Transmitted data return (-) 6 brown Data to Teletype - | ||
+ | |||
+ | Received data send (+) 4 red Data from Teletype + | ||
+ | Received data return (-) 3 black Data from Teletype - | ||
+ | </source> | ||
+ | ===Image details=== | ||
+ | [[File:My Altairclone TTY-RS232 Interface.png|600px]] | ||
+ | [[File:Teletype Model 33 ASR terminal block.png|600px]] | ||
+ | |||
[[Category:Various]] | [[Category:Various]] | ||
[[Category:Teletype]] | [[Category:Teletype]] | ||
+ | [[Category:Operational]] |
Latest revision as of 09:36, 21 August 2015
Contents
20ma current loop <> RS-232 conversion
Vintage PCB
Dig this crazy circuit board man! Still in it's original packaging from Hobby World Electronics in Northridge California.
Additional Resources
- Helpful article, Teletype 101 from vintagecomputer.net
- Another circuit. From [Altairclone] Specifically designed to fit in a Teletype model 33 using only a 12vdc wall wart for power.
- Another circuit I found referenced on the greenkeys email list
My ASR hookup
I built the circuit described above from the altairclone site. I found the Teletype 101 article helpful for identifying the proper terminal strip locations. The interface works. I set baud to 110, with 7 bits and 'mark' parity in TeraTerm on a windows 8 notebook with a Gigaware USB<> serial convereter.
Schematic 1.1
From the original schematic at altairclone I added ASR terminal strip location numbers.
Wiring legend
screw wire schematic
Signal terminal color connection
(Teletype 101 nomenclature) (on ASR) (mine) (altair clone nomenclature)
---------------------------------------------------------------------
Transmitted data send (+) 7 orange Data to Teletype +
Transmitted data return (-) 6 brown Data to Teletype -
Received data send (+) 4 red Data from Teletype +
Received data return (-) 3 black Data from Teletype -